| 1 | Profile A — High-Capacity Intelligent PDU | Large data centers and high-density server rooms | Three-phase, dual-input, separately protected output groups | Up to 250 A per input | 380–415 V AC, 50/60 Hz | IEC 60309 outlets with configurable single-phase branch circuits | Four-pole main isolation, branch MCBs, surge protection, overload alarms | True-RMS current, voltage, power, energy, power factor, temperature and humidity | Ethernet, SNMP, Modbus TCP, Web interface | Powder-coated steel cabinet; forced ventilation; IP31 indoor protection | IEC 61439 design basis; IEC 60309 interface options; CE-oriented documentation | 94/100 |
| 2 | Profile B — Modular High-Availability PDU | Colocation facilities and redundant IT power distribution | Dual independent feeds with modular distribution sections | Up to 160 A per feed | 208–415 V AC, 50/60 Hz | IEC 60320 and IEC 60309 outlets; replaceable branch modules | Input MCCBs, branch MCBs, selective coordination capability | Per-feed and per-branch metering with alarm thresholds | SNMP v1/v2c/v3, Modbus RTU, RS-485 | Modular steel enclosure; front-access service; IP31 | IEC 61439 assembly principles; IEC 61000 EMC considerations | 92/100 |
| 3 | Profile C — Automatic Transfer PDU Switchboard | Critical loads requiring source redundancy | Dual-source automatic transfer configuration | Up to 100 A per source | 208–415 V AC, 50/60 Hz | Single-phase and three-phase branch outputs | Mechanical or solid-state transfer; adjustable transfer delay; bypass option | Source availability, transfer status, load current and alarm history | Ethernet, SNMP, dry contacts, Modbus TCP | Steel floor-standing enclosure; natural or forced ventilation; IP31 | IEC 60947 transfer-switch principles; IEC 61439 panel assembly basis | 90/100 |
| 4 | Profile D — Compact Rack-Level PDU Panel | Small server rooms, edge computing and network cabinets | Single-input, multi-branch distribution | Up to 63 A | 200–240 V AC, 50/60 Hz | IEC 60320 C13/C19 outlets and optional IEC 60309 inlet | Main isolator, branch MCBs, overload protection | Total current, voltage, active power and cumulative energy | Web interface, SNMP, RS-485 | Wall-mounted steel enclosure; passive cooling; IP20–IP31 options | IEC 61439 low-voltage assembly principles; IEC 60320 outlet options | 87/100 |
| 5 | Profile E — Industrial Floor-Standing PDU | Manufacturing plants, automation lines and process equipment | Three-phase radial distribution with segregated sections | Up to 400 A | 380–480 V AC, 50/60 Hz | Industrial socket outlets and hard-wired outgoing feeders | MCCB incomer, branch MCCBs, surge protection and earth-fault options | Incoming current, voltage, power, energy and thermal monitoring | Modbus RTU/TCP, digital alarm contacts | Floor-standing steel enclosure; fan-filter cooling; IP54 option | IEC 61439 design basis; IEC 60529 ingress-protection classifications | 86/100 |
| 6 | Profile F — Energy-Metered Smart PDU | Facilities seeking detailed energy allocation and reporting | Single- or three-phase, metered branch distribution | Up to 125 A | 208–415 V AC, 50/60 Hz | Configurable IEC 60320, IEC 60309 and terminal outputs | MCBs, disconnect switch, branch-level overload alarms | Class 1 energy measurement, voltage, current, power factor and demand | SNMP v3, Modbus TCP, BACnet/IP gateway option | Indoor steel enclosure; passive cooling; IP31 | IEC 61557-12 measurement principles; IEC 61439 assembly basis | 85/100 |
| 7 | Profile G — Outdoor-Protected PDU Switchboard | Telecom shelters, renewable-energy sites and remote facilities | Single- or three-phase distribution with auxiliary control supply | Up to 160 A | 220–480 V AC, 50/60 Hz | Weather-protected sockets and gland-plate cable entries | Main MCCB, branch MCBs, surge protection and residual-current options | Voltage, current, energy, cabinet temperature and door status | Ethernet, 4G gateway option, Modbus RTU, dry contacts | Outdoor steel or polycarbonate enclosure; IP55–IP65; thermostatic heater option | IEC 60529 IP classification; IEC 61439 assembly principles | 84/100 |
| 8 | Profile H — High-Voltage-Input Step-Down PDU | Facilities using high-voltage distribution with low-voltage IT loads | Transformer-fed three-phase distribution | Up to 250 kVA system rating | Input up to 690 V AC; output 208–415 V AC | Low-voltage branch circuits with separated neutral and protective earth | Input isolation, transformer temperature protection, branch MCBs | Input/output voltage, current, energy, transformer temperature and alarms | Modbus TCP/RTU, Ethernet, hardwired alarm contacts | Floor-standing steel assembly; natural or forced ventilation; IP31–IP42 | IEC 61439 assembly basis; IEC 60076 transformer design reference | 83/100 |
| 9 | Profile I — Basic Cost-Optimized PDU Board | Commercial buildings, small workshops and non-critical loads | Single-input, single- or three-phase distribution | Up to 63 A | 220–415 V AC, 50/60 Hz | Terminal blocks, IEC 60309 outlets or local socket configurations | Main isolator, branch MCBs, optional residual-current protection | Local digital meter or no integrated monitoring | Optional RS-485 or alarm contacts | Wall-mounted metal enclosure; passive cooling; IP30–IP41 | IEC 61439 assembly principles; local installation-code compatibility required | 79/100 |
| 10 | Profile J — Portable Service PDU | Temporary installations, testing areas and event infrastructure | Single- or three-phase portable distribution | Up to 63 A | 220–415 V AC, 50/60 Hz | Lockable industrial socket outlets with flexible cable assemblies | Residual-current protection, MCBs, emergency isolation switch | Local current display and fault indication | Usually no network interface; optional digital gateway | Impact-resistant enclosure; IP44–IP65 depending on configuration | IEC 60309 interface options; IEC 60529 ingress-protection classification | 77/100 |