| 1 | Fire assay fusion | A documented fusion procedure that mixes a prepared sample with flux and uses a collector, commonly lead, to gather precious metals into a bead. | Fusion separates the precious-metal-bearing collector from much of the silicate and other gangue material in the sample. |
| 2 | Sample preparation and aliquot | Clear instructions for drying, crushing, pulverizing, splitting, and the mass used for the assay charge. A 30 g charge is common for routine gold fire assay, but it is not universal. | Gold can be unevenly distributed in a sample. Preparation and aliquot size affect how representative the portion tested is. |
| 3 | Cupellation | A stated cupellation step in which the lead collector is oxidized and absorbed into a cupel, leaving a precious-metal bead for measurement. | This is a central part of the conventional lead-collection fire assay sequence and helps isolate the gold-bearing bead. |
| 4 | Gravimetric finish | A gravimetric option for suitable samples, with the bead weighed after the laboratory’s stated separation and measurement steps. | Direct weighing can be appropriate when gold levels are high enough for the method’s working range. |
| 5 | AAS or ICP finish | For lower-level measurements, a validated instrumental finish such as atomic absorption spectrometry (AAS) or inductively coupled plasma (ICP) analysis after fire assay collection. | Instrumental finishes can measure smaller amounts of gold than a balance-based finish; the suitable option depends on the sample and requested reporting range. |
| 6 | Screen fire assay for coarse gold | When coarse or “nuggety” gold is suspected, an optional screen fire assay that assays size fractions separately and combines their results using the documented mass proportions. | Testing a single small aliquot may produce variable results when gold particles are coarse and unevenly distributed. |
| 7 | Quality-control samples | Routine use of appropriate blanks, certified reference materials, and duplicate samples, with quality-control results reviewed against defined acceptance criteria. | These checks help identify contamination, analytical bias, and variability in preparation or measurement. |
| 8 | Detection and reporting limits | Method-specific reporting limits, units, rounding rules, and treatment of results below the reporting limit stated on the quote or certificate. | Reporting limits depend on the sample mass, finish, and procedure; they should not be assumed to be the same across laboratories. |
| 9 | Sample custody and traceability | Unique sample identification, documented receipt and preparation, and a certificate that links reported results to the submitted sample IDs and requested method. | Traceability reduces the risk of sample mix-ups and supports review of results from collection through reporting. |
| 10 | Method scope and accreditation | A current method description and, where required, accreditation whose published scope covers the relevant gold fire assay method and sample type. | Accreditation applies to specific activities in a defined scope; checking that scope is more informative than relying on a general accreditation claim. |