| 1 | 10 kV | Urban and rural medium-voltage distribution | Distribution transformers serving local networks, commonly stepping down to low-voltage service. | Load profile, short-circuit withstand, insulation coordination, and distribution-network losses. |
| 2 | 20 kV | Medium-voltage distribution where this class is adopted | Distribution and network transformers configured for the local 20 kV system. | Compatibility with the regional network standard, insulation level, and available switching equipment. |
| 3 | 35 kV | Distribution and subtransmission | Substation transformers supplying lower-voltage distribution networks or industrial loads. | Voltage regulation, tap-changing requirements, cooling, and protection coordination. |
| 4 | 66 kV | Regional subtransmission in networks using this class | Substation transformers linking 66 kV lines with medium-voltage networks. | Regional network conventions, insulation coordination, and site-specific transport limits. |
| 5 | 110 kV | Regional transmission and major substations | Power transformers connecting transmission networks to 35 kV or lower-voltage systems. | On-load tap changing, system fault levels, cooling capacity, and monitoring provisions. |
| 6 | 220 kV | High-voltage transmission and interconnection | Large substation transformers, including autotransformers where network design calls for them. | Insulation coordination, winding temperature limits, transport planning, and system stability. |
| 7 | 330 kV | High-voltage transmission in regions operating at this level | Grid transformers used at major transmission substations and network interfaces. | Terminal and bushing clearances, lightning-impulse withstand, cooling, and field maintenance access. |
| 8 | 500 kV | Extra-high-voltage bulk power transmission | Large power transformers or autotransformers at 500 kV substations. | High-voltage insulation design, short-circuit strength, transportation constraints, and condition monitoring. |
| 9 | 750 kV | Extra-high-voltage transmission used in parts of China | Substation transformers and autotransformers supporting 750 kV transmission corridors. | High-field insulation coordination, substation layout, transport logistics, and specialized testing. |
| 10 | 1,000 kV AC | Ultra-high-voltage AC bulk transmission | UHV AC substation transformation, typically using large transformer units or bank arrangements selected for the project. | UHV insulation coordination, electric-field control, transport and installation planning, and comprehensive testing. |