| Required continuous torque | Torque needed throughout normal operation, including the load, friction, and any transmission losses. | Calculate from the application load. For rotary power, use T (N·m) = 9550 × P (kW) ÷ n (rpm). For example, 1 kW at 3,000 rpm corresponds to approximately 3.18 N·m. | Application duty profile, load calculations, and the motor’s continuous torque-speed curve. |
| Peak and starting torque | Short-duration torque for acceleration, breakaway, or temporary load increases—and the permitted duration. | Compare required peak torque with the manufacturer’s peak rating and its time limit. Do not treat peak torque as a continuous rating. | Peak torque specification, overload duration, repetition limits, and controller current limits. |
| Speed and operating point | Required minimum, nominal, and maximum speed; confirm torque is available at each operating point. | Check the full torque-speed curve at the actual supply voltage and controller settings. A maximum no-load speed alone does not confirm usable loaded performance. | Torque-speed curves, test conditions, winding configuration, and operating-voltage range. |
| Efficiency and heat | Motor efficiency at the application’s real speed and load, not just a best-case peak figure. | Efficiency is mechanical output power divided by electrical input power. At 1 kW output and 90% efficiency, input power is about 1.11 kW and losses are about 0.11 kW. | Efficiency map or test report identifying the measurement method, operating point, voltage, and temperature. For applicable rotating electrical machines, ask whether testing follows IEC 60034-2-1. |
| Thermal capability | Winding temperature under the intended duty cycle, ambient temperature, cooling method, and mounting arrangement. | Confirm that continuous torque is rated for the actual installation. Enclosure, airflow, mounting, and repeated acceleration can change thermal performance. | Thermal limits, temperature-rise data, duty rating, insulation information, and any required cooling conditions. |
| Duty cycle | Whether operation is continuous, intermittent, reversing, or characterized by frequent starts and stops. | Provide a time-based load and speed profile. Average load alone may conceal demanding starts, braking, or short overloads. | Duty-cycle definition and test results that match the stated operating profile. |
| Electrical compatibility | DC bus voltage, phase current, controller compatibility, back-EMF, and sensor or commutation requirements. | Check both continuous and peak current against the motor and controller ratings. Verify that supply voltage remains within limits during acceleration and regeneration. | Winding data, current ratings, back-EMF constant, wiring diagram, and encoder or Hall-sensor specifications where applicable. |
| Mechanical fit and shaft load | Frame dimensions, shaft and key details, mounting pattern, allowable radial and axial loads, and rotor inertia. | Compare the complete mechanical drawing with the installation. Account for belt tension, coupling forces, and load-induced bearing stress. | Dimensioned drawings, shaft tolerances, bearing information, and allowable-load data. |
| Environmental protection | Exposure to dust, water, vibration, chemicals, and ambient-temperature extremes. | Select an enclosure rating that matches the installation; an IP code describes specified ingress protection, not general resistance to every environment. | Declared IP rating and test documentation. IEC 60529 is the reference standard for IP-code classification. |
| Reliability and service life | Bearing life assumptions, insulation limits, maintenance needs, and performance under the application’s real loads. | Request the assumptions behind any life estimate; service life depends on load, speed, temperature, lubrication, alignment, and operating conditions. | Reliability or endurance test reports, bearing-life calculation basis, maintenance guidance, and warranty terms. |
| Supplier specification quality | Whether ratings are complete, traceable, and stated under clearly defined test conditions. | Check that continuous and peak values are distinguished and that voltage, speed, cooling, ambient temperature, and duty conditions are specified. | Controlled datasheet, test methods, inspection records, change-control process, and written confirmation of deviations. |
| Final selection decision | Fit across torque, speed, efficiency, thermal, electrical, mechanical, and environmental requirements. | Compare candidate motors against the same application profile and verify the intended operating points before approval. | Application-specific sizing review and, where practical, a prototype test under representative load and environmental conditions. |