| Clean, cool water | Carbon graphite / silicon carbide (SiC) | EPDM or NBR | EPDM: approximately −40 to 150°C; NBR: approximately −30 to 100°C | Carbon provides good running-in characteristics in lubricated service. Choose the elastomer based on water temperature and any additives. |
| Hot water or aqueous service | Carbon graphite / SiC, or SiC / SiC for more demanding wear conditions | EPDM, subject to grade and water chemistry | EPDM compounds commonly cover approximately −40 to 150°C; verify the specific grade for hot water or steam | Check pressure, thermal cycling, water treatment chemicals, and the seal design’s operating limits. Elastomer limits alone do not define the seal’s maximum temperature. |
| Mineral oil, lubricating oil, or fuel | Carbon graphite / SiC | NBR for many oils; FKM for higher-temperature service when chemically compatible | NBR: approximately −30 to 100°C; FKM: approximately −20 to 200°C | Compatibility varies with oil formulation, fuel blend, additives, and temperature. Some FKM grades have limited resistance to certain fuels or low temperatures. |
| Aromatic or chemically aggressive hydrocarbons | SiC / SiC, subject to chemical compatibility of the SiC grade | FKM or FFKM; confirm compatibility with the exact fluid | FKM: approximately −20 to 200°C; FFKM: often approximately −20 to 300°C, depending on grade | These are broad guide ranges, not guarantees. Solvent mixtures, concentration, pressure, and exposure time can change compatibility significantly. |
| Abrasive slurry or water containing solids | SiC / SiC; consider a suitable flush or seal arrangement | EPDM or FKM, selected for the carrier fluid and temperature | EPDM: approximately −40 to 150°C; FKM: approximately −20 to 200°C | Hard faces can improve resistance to abrasive wear, but particle size, solids loading, face lubrication, and flushing are critical to service life. |
| Acidic or alkaline aqueous solution | Often SiC / SiC, after checking the specific fluid and material grades | EPDM may suit some aqueous chemicals; FKM or FFKM may suit other services | Use the selected compound’s published range; typical broad ranges are EPDM −40 to 150°C and FKM −20 to 200°C | There is no universally compatible elastomer. Confirm concentration, temperature, and chemical compatibility; some SiC grades and binders may also be unsuitable. |