| 1 | Confocal Raman microscope | Common options include 532 nm, 633 nm, and 785 nm | Micro-scale chemical identification, materials research, and spatially resolved analysis | Confirm the complete microscope’s laser classification, enclosure and interlock design, beam-access controls, and wavelength-specific eye-protection requirements. | Check local microscope and laser service capability, optical alignment support, preventive-maintenance intervals, and availability of replacement components. | Verify applicable laser, electrical-safety, and EMC requirements for the destination market; confirm that the delivered configuration and documentation match the approved configuration. |
| 2 | 785 nm benchtop Raman analyzer | 785 nm | Routine identification of powders, solids, and packaged samples; often selected to reduce fluorescence relative to visible excitation. | Do not infer laser class from wavelength alone. Request the system’s classification, user-accessible emission information, interlock details, and operating instructions. | Confirm calibration and verification procedures, response times, remote-support availability, and access to trained service personnel in the buyer’s region. | Check local product-safety and EMC requirements, import documentation, power requirements, and any applicable requirements for laser products. |
| 3 | 532 nm visible Raman system | 532 nm | Applications requiring strong Raman scattering, including selected inorganic materials, pigments, and crystalline samples. | Visible green beams can present significant eye hazards. Verify enclosure, interlocks, beam containment, warning labels, and wavelength-appropriate protective measures. | Ask whether service staff can support visible-laser alignment and whether alignment procedures are restricted to trained personnel. | Confirm the applicable laser-product and electrical/EMC requirements, as well as local workplace laser-safety rules for installation and use. |
| 4 | 1064 nm FT-Raman system | 1064 nm | Fluorescence-prone samples and materials for which near-infrared excitation may improve usable Raman measurements. | Near-infrared radiation is invisible. Confirm emission indicators, enclosure and interlocks, beam-path controls, and suitable user training; do not rely on visual detection of a beam. | Check detector and laser service arrangements, system verification methods, specialist repair availability, and expected instrument downtime. | Verify the complete instrument’s laser classification and applicable local product-safety, electrical, and EMC documentation; confirm that the stated wavelength and configuration are documented. |
| 5 | Raman system with fiber-optic probe | Common options include 532 nm, 785 nm, or 1064 nm | Remote measurements, process sampling, and analysis where a microscope stage is impractical. | Assess laser emission at the probe tip, connector handling, interlocks, and safe procedures for disconnected or damaged fibers. Fiber transmission does not by itself make a system eye-safe. | Check probe and fiber replacement lead times, connector compatibility, cleaning guidance, field-service coverage, and support for probe calibration or verification. | For process or hazardous-area installations, separately verify site, equipment, and area-classification requirements; a Raman system’s general conformity does not establish suitability for a hazardous location. |
| 6 | Raman imaging and mapping microscope | Common options include 532 nm, 633 nm, or 785 nm | Chemical-distribution maps and spatially resolved characterization of heterogeneous samples. | Check the laser classification for all installed excitation sources and operating modes, including accessible emission during mapping and any service or alignment state. | Confirm software support, stage and detector servicing, data-backup guidance, application training, and availability of qualified local engineers. | Review electrical and EMC compliance for the full system, including accessories and computer components supplied as part of the installation. |
| 7 | Low-frequency Raman configuration | Common excitation options include 532 nm, 633 nm, or 785 nm, subject to system configuration | Study of low-frequency vibrational modes in selected materials, crystals, and nanostructures. | Confirm the laser-safety classification and safeguards for the actual excitation source; verify that filters and optical components do not compromise the protective enclosure. | Ask about specialist optical servicing, verification samples or procedures, and support for configuration-specific measurement methods. | Confirm that the exact configuration, accessories, and operating documentation are covered by the destination-market conformity documentation. |
| 8 | Automated multi-sample Raman workstation | Common options include 532 nm, 633 nm, or 785 nm | Repeatable analysis across multiple samples with reduced manual handling and standardized workflows. | Review enclosure and interlock behavior during automated operation, loading, fault conditions, and maintenance; verify that users cannot access hazardous emissions during normal operation. | Check automation-software updates, sample-stage support, operator training, maintenance coverage, and service response for production-impacting faults. | Check the compliance status of the integrated system and accessories, along with local installation, electrical supply, and workplace-safety requirements. |
| 9 | Portable or field Raman analyzer | Often 785 nm; other wavelengths depend on the design | On-site screening and identification when laboratory infrastructure is unavailable. | Check the classification and safeguards in handheld, docked, and charging modes; review trigger controls, user warnings, and safe-use instructions for field operators. | Confirm regional repair options, battery replacement and transport guidance, software support, calibration checks, and availability of loan units if needed. | Verify market-specific product documentation, radio approvals if wireless functions are present, battery transport rules, and applicable import requirements. |
| 10 | Process Raman analyzer with remote sampling interface | Common options include 532 nm, 785 nm, or 1064 nm, depending on the application | In-line or at-line monitoring of process streams, materials, or reaction changes. | Assess the laser and probe interface as installed, including beam containment, fiber connections, maintenance access, and site-specific operating procedures. | Confirm installation and commissioning support, site-response commitments, spare-probe availability, software lifecycle, and integration support for process-control systems. | Determine whether the installation requires additional process, environmental, or hazardous-area approvals. Verify these separately from general instrument conformity. |