| 1. Match the device to the measurement task | Confirm that the instrument measures the required vibration quantity, such as acceleration, velocity, or displacement, and supports the necessary frequency range and units. | Compare the device specifications with the machine, measurement method, and applicable procedure. Check whether it reports RMS, peak, or peak-to-peak values as needed. | Different quantities and frequency ranges suit different applications; a device outside the required range may produce results that are unsuitable for the task. | Check that specifications and measurement modes are documented and that firmware or software updates do not remove required functionality. |
| 2. Test everyday usability | Assess menu clarity, display readability, physical controls, measurement setup, and how easily users can identify units and settings. | Have intended users complete a representative measurement without coaching. Verify that they can select the correct mode, save a reading, and retrieve it. | Clear operation helps reduce setup mistakes and makes measurements more consistent across users and shifts. | Look for accessible operating instructions, training materials, and a defined process for onboarding new users. |
| 3. Check sensor and mounting options | Review sensor type, cable or wireless connection, mounting accessories, and whether the sensor is suitable for the measurement location. | Confirm that the sensor can be attached securely and repeatably. For accelerometers, consider how mounting method and surface condition can affect high-frequency response. | Loose or inconsistent mounting can alter readings, particularly at higher frequencies, and can make comparisons less reliable. | Confirm that replacement sensors, cables, connectors, and mounting accessories can be obtained and are compatible with the device. |
| 4. Review calibration and traceability | Ask what calibration is supplied, which measurement functions are covered, and whether results are traceable to recognized national or international measurement standards. | Inspect a sample calibration certificate for the instrument or sensor. Check its identification, calibration date, measured points, results, and stated uncertainty where applicable. | Calibration records help establish measurement confidence. Traceability alone does not mean a calibration was performed by an accredited laboratory. | Check whether calibration services are available, whether accredited calibration is offered when required, and how certificates and records are retained. |
| 5. Plan a sensible recalibration schedule | Consider the manufacturer’s guidance, usage frequency, operating environment, handling history, and the consequences of inaccurate results. | Set the interval through a documented process based on applicable requirements and experience. Review it after damage, unusual results, or significant changes in use. | There is no single recalibration interval suitable for every device and application; an interval should reflect risk and measurement needs. | Ask about calibration turnaround time, service documentation, and procedures for handling devices that fail calibration. |
| 6. Check data handling and reporting | Assess storage capacity, export formats, software compatibility, time stamps, measurement labels, and the ability to preserve units and settings with results. | Perform a trial export and confirm that readings can be transferred, reviewed, and backed up using the organization’s existing workflow. | Consistent records make it easier to compare measurements over time and support maintenance decisions and audits. | Review software support terms, file-format accessibility, update policies, and options for exporting data if software support changes. |
| 7. Evaluate support and total ownership needs | Consider warranty terms, repair options, technical support, spare-part availability, battery requirements, and expected service life. | Request clear information on service routes, typical repair and calibration turnaround, warranty coverage, and the availability of manuals and parts. | A device is only useful over time if it can be maintained, repaired, calibrated, and used reliably in its operating environment. | Compare documented service commitments and lifecycle costs, including calibration, accessories, software, repairs, and eventual replacement. |