| 1 | Fixed-Mounted ACB with LSI Protection | Fixed chassis; front-accessible electronic trip unit | LSI | 630–6,300 A | 3P | 50/60 Hz | Up to 690 V AC under IEC applications; up to 600 V AC in common UL applications | Approximately 42–100 kA, depending on frame and voltage | Time-current coordination with downstream MCCBs and fuses; no dedicated ground-fault element | Main incomers, industrial distribution boards, and cost-sensitive installations |
| 2 | Fixed-Mounted ACB with LSIG Protection | Fixed chassis with integral ground-fault sensing | LSIG | 630–6,300 A | 3P | 50/60 Hz | Up to 690 V AC under IEC applications; up to 600 V AC in common UL applications | Approximately 42–100 kA, depending on frame and voltage | Enhanced selectivity using adjustable ground-fault pickup and delay; suitable for grounded systems | Industrial incomers where equipment protection and ground-fault coordination are required |
| 3 | Drawout ACB with LSI Protection | Withdrawable cassette with connected, test, and disconnected positions | LSI | 800–6,300 A | 3P | 50/60 Hz | Up to 690 V AC under IEC applications; up to 600 V AC in common UL applications | Approximately 50–100 kA, depending on frame and voltage | Maintains long- and short-time coordination while allowing rapid breaker isolation for maintenance | Critical switchboards, data centers, process plants, and high-availability facilities |
| 4 | Drawout ACB with LSIG Protection | Withdrawable ACB with secondary disconnects and ground-fault protection | LSIG | 800–6,300 A | 3P | 50/60 Hz | Up to 690 V AC under IEC applications; up to 600 V AC in common UL applications | Approximately 50–100 kA, depending on frame and voltage | Four-function coordination for mains, ties, generators, and downstream feeder protection | Mission-critical low-voltage switchgear requiring maintainability and ground-fault selectivity |
| 5 | High-Interrupting-Capacity ACB with LSI | Fixed or drawout construction using a high-duty arc-interruption system | LSI | 800–6,300 A | 3P | 50/60 Hz | Commonly 400–690 V AC, depending on the applicable standard and design | Approximately 65–150 kA at the rated voltage, subject to the product test rating | Short-time withstand and adjustable short-time delay support selective coordination at high prospective fault levels | Large industrial plants, utility substations, and high-short-circuit-capacity switchboards |
| 6 | High-Interrupting-Capacity ACB with LSIG | Fixed or drawout high-duty construction with ground-fault function | LSIG | 800–6,300 A | 3P | 50/60 Hz | Commonly 400–690 V AC, depending on the applicable standard and design | Approximately 65–150 kA at the rated voltage, subject to the product test rating | Supports selective ground-fault protection in addition to high-level short-circuit coordination | Large grounded systems where both high fault duty and ground-fault discrimination are necessary |
| 7 | Four-Pole ACB with LSI Protection | Four current-carrying poles; neutral pole may be switched or solid, as specified | LSI | 630–6,300 A | 4P | 50/60 Hz | Up to 690 V AC under IEC applications; up to 600 V AC in common UL applications | Approximately 42–100 kA, depending on frame and voltage | Allows neutral isolation where required; coordination remains based on phase overcurrent functions | Transfer systems, separately derived sources, and installations requiring switched neutral conductors |
| 8 | Four-Pole ACB with LSIG Protection | Four-pole fixed or drawout construction with adjustable ground-fault protection | LSIG | 630–6,300 A | 4P | 50/60 Hz | Up to 690 V AC under IEC applications; up to 600 V AC in common UL applications | Approximately 42–100 kA, depending on frame and voltage | Useful for ground-fault coordination on systems where the neutral must be switched or monitored | Automatic transfer equipment, emergency power systems, and low-voltage main-tie-main assemblies |
| 9 | Generator-Incomer ACB with LSI Protection | Usually drawout; designed for generator source connection and frequent operation | LSI | 800–4,000 A | 3P or 4P | 50/60 Hz | Commonly 400–690 V AC, depending on generator and switchboard design | Approximately 42–85 kA, subject to generator contribution and tested rating | Short-time delay can coordinate with downstream feeders; instantaneous pickup may need adjustment because generator fault current is limited | Standby generators, prime-power systems, and synchronizing switchboards |
| 10 | Main-Tie-Main ACB with LSIG Protection | Interlocking arrangement using two incomers and one bus-tie breaker | LSIG | 800–6,300 A per breaker | 3P or 4P | 50/60 Hz | Up to 690 V AC under IEC applications; up to 600 V AC in common UL applications | Approximately 50–100 kA, depending on system configuration and voltage | Supports source-to-source and feeder selectivity; interlocking and protection settings must be coordinated as a system | Dual-source facilities, hospitals, data centers, utilities, and resilient industrial distribution |