| 1 | mA Loop Calibrator | Measures and sources 0–20 mA or 4–20 mA signals; may provide loop power. | ±0.02% to ±0.05% of reading | mA, %, VDC | Current measure/source, loop-powered transmitter testing, 24 V loop supply, step and ramp output. | Control-valve loops, pressure transmitters, level transmitters, flow transmitters and analog input cards. | Supports verification of the analog signal chain used with industrial transmitters; it does not replace a complete transmitter performance test. | Source accuracy, loop-load capacity, compliance voltage, fuse protection, battery life and hazardous-area certification. |
| 2 | Multifunction Process Calibrator | Measures and sources electrical, temperature and selected process signals in one instrument. | Typically ±0.02% to ±0.05% for electrical functions | mA, V, Ω, frequency, pulse, °C, °F | Signal simulation, RTD and thermocouple measurement, frequency/pulse testing, ramping and switch testing. | General commissioning, maintenance workshops, plant shutdowns and multi-instrument service work. | Useful for checking input and output signals associated with transmitter calibration and performance evaluation. | Number of supported sensor types, cold-junction compensation, channel isolation, display resolution and documentation capability. |
| 3 | Pressure Calibrator | Measures pressure and may generate pneumatic or hydraulic test pressure. | Approximately ±0.025% to ±0.1% of full scale | Pa, kPa, bar, mbar, psi, inH₂O, mmHg | Pressure measurement, pressure generation, leak testing, zero adjustment and pressure-switch testing. | Pressure transmitters, gauges, pressure switches, safety systems and process control loops. | Provides the reference pressure needed to evaluate transmitter input-to-output behavior under IEC 60770-related testing practices. | Pressure range, media compatibility, overpressure protection, stabilization time, resolution and calibration traceability. |
| 4 | Temperature Calibrator | Measures or simulates RTDs, thermocouples and resistance-based temperature signals. | Electrical simulation typically ±0.02% to ±0.05%; sensor accuracy depends on type | °C, °F, Ω, mV | RTD simulation, thermocouple simulation, cold-junction compensation, sensor measurement and transmitter input testing. | Temperature transmitters, ovens, furnaces, reactors, heat exchangers and HVAC process loops. | Enables controlled input simulation when checking temperature transmitter linearity, hysteresis and repeatability. | Supported RTD and thermocouple standards, cold-junction accuracy, source stability, insulation resistance and temperature range. |
| 5 | Documenting Process Calibrator | Measures process signals while storing calibration procedures, results and device records. | Typically ±0.02% to ±0.05% for electrical measurement functions | mA, V, Ω, frequency, pressure units, temperature units | As-found/as-left records, automated test sequences, error calculation, pass/fail evaluation and data export. | Quality systems, regulated production, maintenance management and multi-point instrument calibration. | Helps document transmitter performance characteristics such as input/output error, repeatability and adjustment results. | Memory capacity, audit trail, calibration software compatibility, report formats, cybersecurity and data retention. |
| 6 | HART-Enabled Process Calibrator | Combines analog signal measurement with communication and configuration over HART networks. | Analog measurement typically ±0.02% to ±0.05% of reading | mA, %, process variable units and device-specific engineering units | Digital trim, sensor trim, loop test, device-variable review, range configuration and status diagnostics. | Smart pressure, temperature, flow and level transmitters using HART communication. | Can support assessment of both the analog output and configured transmitter parameters used during performance verification. | HART revision support, device description coverage, loop resistance, battery life, intrinsically safe approval and usability. |
| 7 | Fieldbus or Digital Transmitter Tester | Communicates with digital field instruments and verifies selected variables and diagnostic data. | Depends on the internal reference and the connected transmitter | Digital process variables, %, engineering units | Device identification, configuration review, status diagnostics, digital value monitoring and network checks. | FOUNDATION Fieldbus, PROFIBUS PA or other digital instrumentation maintenance environments. | Useful for reviewing digital transmitter behavior; IEC 60770 performance results must still account for the complete measurement system. | Protocol support, device interoperability, power conditioning, network safety, device-description updates and diagnostic depth. |
| 8 | Electrical Signal Calibrator | Sources and measures voltage, current, resistance, frequency and pulse signals. | Approximately ±0.01% to ±0.05% of reading | mV, V, µA, mA, Ω, Hz, pulses | Precision sourcing, signal measurement, frequency generation, pulse simulation and input-card verification. | PLC and DCS analog inputs, signal conditioners, control panels and instrument benches. | Verifies the electrical portions of transmitter loops and control-system input/output channels. | Output resolution, channel isolation, maximum drive current, frequency accuracy, burden voltage and thermal stability. |
| 9 | Pressure-and-Loop Combination Calibrator | Measures pressure and electrical loop signals simultaneously for transmitter testing. | Pressure typically ±0.025% to ±0.1% full scale; current ±0.02% to ±0.05% | bar, psi, kPa, mA, V, % | Pressure input with mA output monitoring, automatic error calculation, leak testing and transmitter trim support. | Pressure transmitter calibration, impulse-line checks, custody-transfer support and field troubleshooting. | Directly supports comparison of applied pressure against transmitter output during input/output performance checks. | Pressure module interchangeability, simultaneous measurement, impulse-line accessories, ruggedness and environmental rating. |
| 10 | Portable High-Accuracy Reference Calibrator | Provides laboratory-grade reference measurement or source capability for field and workshop use. | Approximately ±0.005% to ±0.02% of reading, depending on function | mV, V, mA, Ω, frequency, pressure and temperature units | High-resolution measurement, stability monitoring, automated calibration, external standards and traceable reporting. | Primary maintenance standards, calibration laboratories, critical process plants and verification of working calibrators. | Suitable as a reference instrument when evaluating transmitter accuracy, repeatability, hysteresis and dead band. | Traceable calibration certificate, long-term stability, environmental compensation, uncertainty budget and accredited laboratory support. |