| Fan does not turn on | Tripped circuit breaker, disconnected power, faulty switch, damaged wiring, or failed motor | Check the breaker and confirm the hood is connected to power. With power switched off, check whether the filters are seated correctly. | Power or switch issues can often be repaired. A technician can test the motor and electrical connections. | Consider replacement if the motor or control parts are unavailable, or if multiple components have failed. |
| Fan runs but airflow is weak | Grease-clogged filters, blocked duct, closed damper, or restricted exterior vent | Clean reusable filters according to the hood manual. Check that the duct outlet and damper are not visibly obstructed. | Cleaning filters, clearing an accessible obstruction, or correcting a loose duct connection may restore airflow. | Replacement may be warranted if the fan remains ineffective after the duct and filters are checked, and the unit is undersized or has a failing motor. |
| Fan makes a rattling or scraping sound | Loose filter or cover, debris near the blower, worn bearings, or an unbalanced fan wheel | Turn off power before checking that removable filters and covers are secure. Do not reach into the blower while it is connected to power. | A loose part or accessible debris may be corrected. A technician can inspect the blower assembly and motor. | Replace the unit if the blower or motor is seriously damaged and repair is impractical. |
| Fan hums but the blades do not move | Obstructed blower, failing motor, or an electrical component fault | Switch off the fan and power before any visual inspection. Do not try to push the blades while the unit is energized. | A technician may be able to remove an obstruction or replace a serviceable motor component. | Replacement may be preferable if the motor assembly is not serviceable or the unit has other significant faults. |
| Fan works intermittently or only on some speeds | Worn switch, faulty electronic control, loose connection, or failing motor | Note which settings fail and whether the problem changes when the controls are used. Avoid opening electrical compartments. | A technician can test and replace a failed switch or control if compatible parts are available. | Consider a new unit if replacement controls are unavailable or the repair approaches the cost of a suitable replacement. |
| Fan runs, but smoke or cooking odors linger | Dirty filters, poor ducting, blocked termination, inadequate airflow, or unsuitable fan capacity for the installation | Clean filters and check for visible duct restrictions. Confirm that the fan exhausts outdoors if the system is designed to do so. | Correcting a duct blockage, loose connection, or maintenance issue may improve performance. | Replacement may be appropriate if the fan is damaged or cannot provide suitable airflow for the cooking area and duct layout. |
| Fan trips the breaker or produces a burning smell | Possible short circuit, overheated motor, damaged wiring, or another electrical fault | Stop using the fan and switch off its circuit if safe to do so. Do not reset the breaker repeatedly or continue testing the unit. | Have a qualified technician or electrician diagnose the fault before the fan is used again. | Replace the fan if inspection finds serious motor or electrical damage, following professional advice. |